Product Overview
The Data Center Continuous Power Diesel Generator delivers certified ISO 8528-G3/G4 transient performance, providing unlimited operational runtime under variable loads to guarantee 99.999% uptime for Tier III and IV facilities.
Technical Specifications & DCC Load Compliance Matrix
|
Engineering Classification |
Technical Parameter |
Specification Range / Standard Compliance |
|
Power Rating Profiles |
Power Output Envelope |
1000 kVA – 3500 kVA+ engineered capacity |
|
Generation Voltage Configurations |
400V / 480V / 6.3kV / 10.5kV / 11kV / 13.8kV |
|
|
Power Factor Allocation |
0.8 lagging |
|
|
Data Center Continuous Capability |
100% continuous output operation |
|
|
Transient and Dynamics |
Response Classification |
ISO 8528-G3 / G4 compliant |
|
First-Step Block Load Acceptance |
≤ 10 seconds stabilization |
|
|
Steady-State Voltage Tolerance |
≤ ±0.5% |
|
|
Steady-State Frequency Tolerance |
≤ ±0.25% |
|
|
Excitation & Harmonics |
Excitation System Architecture |
PMG or AREP excitation system |
|
Short-Circuit Fault Sustainment |
300% rated current for 10 seconds |
|
|
Waveform Distortion Control |
THD < 3% line-to-line |
|
|
Telephone Interference Indices |
TIF < 50; THF < 2% |
|
|
Mechanical Architecture |
Engine Topography |
V-type 12/16/20-cylinder diesel engine |
|
Speed Governing System |
Digital ECU with CAN-bus SAE J1939 |
|
|
Alternator Thermal Profile |
Class H insulation / Class F or B rise |
|
|
Control & DCIM Telemetry |
Control Hardware Platform |
Deep Sea / ComAp / Woodward controller |
|
Parallel Synchronization Speed |
Dead Bus Merging ≤ 15 seconds |
|
|
Network Communication Protocols |
Modbus RTU / TCP-IP / SNMP |
|
|
Environmental & Safety |
Emission Standard Mapping |
EPA Tier 2 / Tier 4 / EU Stage V |
|
Cold-Start Thermal Support |
Jacket water and anti-condensation heaters |
|
|
Manufacturing Certifications |
CE / UL 2200 / ISO 9001 / ISO 14001 |
Factory Acceptance Testing (FAT)
Core Testing Protocols
Transient Step Testing: High-speed oscilloscopes record voltage recovery during 0% to 100% block-load step execution.
Thermal Saturation Run: Units undergo a 4-hour continuous 100% DCC load test monitored via infrared thermography.
Overload Capacity Validation: Alternators complete a 1-hour verification run at 110% of rated continuous power.
Witnessed FAT Options
Physical Witnessed FAT: Procurement engineers access live test bench instrumentation from the factory viewing gallery.
Digital Remote FAT: Multi-angle HD live-streaming provides direct, unedited telemetry feeds from the active test cell.
Quality Dossier Delivery: Every shipment includes certified transient response curves, vibration analysis data, and fuel logs.
International Standards, Emissions, and Certifications
|
Regulatory Body / Standard |
Operational Infrastructure Impact |
|
UL 2200 |
Validates comprehensive electrical and mechanical safety for North American installations. |
|
ISO 8528-5 (G3/G4) |
Establishes strict voltage and frequency deviation limits required for sensitive IT infrastructure. |
|
CE Marking |
Ensures compliance with European health, safety, and environmental protection legislation. |
|
IEC 60034-1 |
Defines standard rating, cooling, and insulation performance criteria for the alternator. |
|
ISO 9001 / 14001 |
Guarantees audited factory manufacturing consistency and sustainable production workflows. |
Applications
|
Application Field |
How It Was Used |
Benefits |
|
Hyperscale Facility |
Multi-megawatt parallel backup configuration |
Maintains continuous cloud infrastructure uptime |
|
Colocation Centers |
Integrated into Tier III/IV power topology |
Supports tenant SLA compliance |
|
Enterprise Infrastructure |
Connected to core UPS networks |
Prevents data and hardware loss |
|
Edge Computing Nodes |
Distributed standalone backup installation |
Reduces emergency power latency |
|
Financial Clearing Hubs |
Automated fast-start standby configuration |
Improves grid instability protection |
Lifecycle Engineering Services & Long-Term Parts Availability
Core Support Framework
Pre-Installation Support: Factory engineers provide AutoCAD layouts, Revit BIM models, and airflow calculations matching existing facility footprints.
System Customization: We engineer automated fuel networks and modify controller firmware for Modbus/SNMP BMS and DCIM integration.
Global Supply Chain & Parts Availability
Maintenance Kits: Pre-packaged kits with genuine filters, gaskets, and sensors are stocked for immediate worldwide dispatch.
Component Guarantee: Digital AVRs, electronic governors, and control modules are maintained in inventory for accelerated shipping.
Engineering Hotline: Procurement teams gain direct Tier-3 factory engineer access for troubleshooting and firmware updates without ticketing delays.