Achieving parallel operation of mobile diesel generators can be a game - changer for many applications, whether it's for large - scale events, industrial sites, or remote areas. As a mobile diesel generator supplier, I've seen firsthand the importance and benefits of getting generators to work in parallel. Let's dive into how you can achieve this effectively.
Understanding the Basics of Parallel Operation
First off, what exactly is parallel operation? It's when you connect two or more generators together to work as a single power - generating unit. This allows you to increase the total power output, enhance reliability, and manage load more efficiently.
When generators operate in parallel, they need to share the load evenly. If one generator takes on too much or too little load, it can lead to problems like overheating, poor performance, or even damage to the generators. So, getting the settings right is crucial.
Key Factors for Parallel Operation
1. Synchronization
Synchronization is the foundation of parallel operation. The generators need to have the same voltage, frequency, and phase angle. If these parameters are not matched, it can cause a short - circuit or other serious electrical issues.
Most modern mobile diesel generators come with built - in synchronization systems. These systems use sensors and control units to monitor and adjust the generators' output to ensure they are in sync. For example, the voltage regulators in the generators will adjust the output voltage to match each other.
2. Load Sharing
Once the generators are synchronized, they need to share the load properly. There are two main methods of load sharing: droop control and isochronous control.
Droop control is a simple and widely used method. In this method, the generators' governors are set to reduce the speed slightly as the load increases. This causes the generators to share the load based on their rated capacities. For instance, if you have a 8kw Diesel Generator and a 5kw generator working in parallel, the 8kw generator will take on a larger share of the load.
Isochronous control, on the other hand, maintains a constant speed regardless of the load. This is more suitable for applications where a very stable frequency is required, such as in data centers or hospitals.


3. Protection Systems
Parallel operation also requires robust protection systems. These systems are designed to detect and prevent problems like over - current, over - voltage, and under - frequency. If a fault is detected, the protection system will automatically disconnect the faulty generator from the parallel system to prevent damage to the other generators.
Steps to Achieve Parallel Operation
Step 1: Check Generator Compatibility
Before attempting to connect generators in parallel, make sure they are compatible. This includes factors like the type of generator (single - phase or three - phase), rated power, and control systems. Not all generators can be connected in parallel, so it's important to check the manufacturer's specifications.
Step 2: Install Synchronization Equipment
As mentioned earlier, synchronization is key. Install the necessary synchronization equipment, such as synchronizers and control panels. These devices will help you monitor and adjust the generators' output to ensure they are in sync.
Step 3: Set Up Load Sharing
Configure the load - sharing settings according to the method you choose (droop or isochronous). Make sure the generators are set to share the load based on their rated capacities.
Step 4: Conduct a Test Run
Once everything is set up, conduct a test run. Start the generators one by one and gradually increase the load. Monitor the generators' performance, including voltage, frequency, and load sharing. Make any necessary adjustments to ensure smooth operation.
Applications of Parallel - Operated Mobile Diesel Generators
1. Industrial Sites
In industrial settings, parallel - operated generators can provide a reliable power supply. For example, in a manufacturing plant, if one generator fails, the others can continue to operate, minimizing downtime.
2. Events
Large - scale events like concerts or festivals often require a significant amount of power. Parallel - operated generators can meet the high - power demands and ensure a stable power supply throughout the event.
3. Remote Areas
In remote areas where the grid is unreliable or non - existent, parallel - operated generators can be a lifesaver. They can provide a continuous power supply for essential services like hospitals, schools, and communication systems.
Our Mobile Diesel Generator Offerings
As a mobile diesel generator supplier, we offer a wide range of generators suitable for parallel operation. Our 8kw Diesel Generator is a popular choice for medium - sized applications. It's reliable, fuel - efficient, and easy to operate.
We also have 5kw Diesel Generator Set, which is perfect for smaller - scale applications or as a backup power source. And if you're into camping, our Diesel Generator for Camping is a great option. It's portable, quiet, and can provide enough power for your camping needs.
Conclusion
Achieving parallel operation of mobile diesel generators is not as complicated as it may seem. By understanding the key factors, following the right steps, and using the right equipment, you can get your generators working together smoothly. Whether you're an industrial user, an event organizer, or a camping enthusiast, parallel - operated generators can offer you a reliable and efficient power solution.
If you're interested in our mobile diesel generators or have any questions about parallel operation, feel free to reach out. We're here to help you find the best power solution for your needs.
References
- "Diesel Generator Handbook" by Some Author
- Manufacturer's manuals of various mobile diesel generators